Geotec - Needle Punched Polypropylene Geotextile 700gsm

Public Channel / Data Sheets

Needle Punched Non-Thermally Bonded Nonwoven
700 % Polypropylene Geotextile

GEOTEC 700 GSM is a needle punched & Non-Thermally Bonded nonwoven geotextile
composed of 100 % virgin Polypropylene staple fibres which are formed into a stable
network such that the fibers retain their relative position and will meet the following
Average Values when tested accordance with the standards listed below.

Durability
predicted to be durable for a minimum of 25 years in natural soil with 4 < pH < 9
and soil temperatures < 25° C
Maximum allowed time between installation and covering of Geotextile is 02 weeks.

Share on Social Networks

Share Link

Use permanent link to share in social media

Share with a friend

Please login to send this document by email!

Embed in your website

Select Link to start with 

2. TDS - WP - WS1 - 000_01 / 21 1. The properties values listed above are effective from 06/2017 and are subjected to change without notice . 2. The values reported herein are, to best of our knowledge, accurate and reflect the average results obtained in our Laboratory . ROADS RAILWAYS FOUNDATON & RETAINING WALLS DRAINAGE EROSION CONTROL SYSTEMS RESERVOIRS & DAMS CANALS TUNNELS & UNDER GROUND STRUCTURES SOLID WASTE LIQUID WASTE NOTE: The information contained in this DATA SHEET, as well as our advice, both written as oral or provided through testing, are based on our experience, and they do not constitute any product guarantee for the installer, who must take them as simple orientations, provided strictly as info rmation. We recommend to study deeply all information provided before proceeding to the use or application of any of our products, and strongly advise to conduct tests “on - site” in order to determine their convenience for a specific project. Our recommenda tions do not exempt of the obligation that installers have to deeply know the right application method for these systems before they use them, as well as to conduct as many preliminary tests as possible if there are any doubts about the appropriate system to use. The application, use and processing of our products are beyond our control, and therefore under the exclusive responsibility of the installer. In consequence, the installer will be the only responsible of any damage or prejudice derived from the pa rtial or total in - observation of our indications, and in general, of the inappropriate use or application of these materials. Saja a Industrial Area behind Sharjah Cement Factory, Sharjah U.A.E. Email: Inquiry@royalwayindustries.com PO BOX: 65034 Tel: +971 6 5679000 Website: www.royalwayindustries.com ROYAL WAY INDUSTRIES LLC Page 2

1. TDS - WP - WS1 - 000_01 / 21 GEOTEC 7 0 0 GSM is a needle punched & non Thermally Bonded nonwoven geotextile composed of 100 % virgin Polypropylene staple fibres which are formed into a stable network such that the fibers retain their relative position and will meet the following Average Values when tested accordance with the standards listed below. GEOTEC 7 0 0 GSM inert to biological degradation and resists naturally encountered chemicals , alkalis, and acids. POLYMER DENSITY MELTING POINT CONSTRUCTION 100% Polypropylene 0.91 km/cm 3 160 - 171 °C Staple Fibers TEST METHOD VALUE TOLERANCE Mechanical properties Grab Strength - MD ASTM D 4632 3 7 0 0 N - 15% Grab Strength - CD 3 7 0 0 N - 15% Grab Elongation - MD 7 0 % - 25% Grab Elongation - C D 7 5 % - 25% Trapezoidal Tear strength - MD ASTM D 4533 1 25 0 N - 15% Trapezoidal Tear Strength - CD 1 25 0 N - 15% Index Puncture Resistance ASTM D 4833 1 200 N - 15% CBR Puncture Resistance ASTM D 6241 9 .50 kN - 15% UV Resistance ASTM D 4355 70/500 %hrs - 15% Hydraulic properties Permeability ASTM D 4491 29 x 10 ̄³ m/s ± 30% Water Flow normal to the plane ASTM D 4491 29 l/m².s ± 30% Apparent Opening Size ASTM D 4751 6 3 μm ± 30% Physical properties Thickness* under 2 kPa ASTM D 5199 5 .00 mm ± 20% Weight ASTM D 5261 7 0 0 g/m² ± 10% * At the time of manufacturing. Handling, storage, and shipping may change these properties. Packaging Roll Dimensions (W) mtr 3.0 / 6.0 ± 0.8% Roll Dimensions (L) 50 ± 2.0% Square mtr Per Roll Square mtr 150 / 300 - Estimated Roll Weight Kg 105 / 21 0 - Estimated Roll Diameter cm 5 5 ± 10% Durability predicted to be durable for a minimum of 25 years in natural soil with 4 < pH < 9 and soil temperatures < 25° C Maximum allowed time between installation and covering of Geotextile is 02 weeks. The construction of the geotextile makes this product ideal for the following applications. GEOTEC 7 0 0 GSM Needle Punched Non Thermally Bonded Nonwoven 100 % Polypropylene Geotextile Page 1 TECHNICAL SPECIFICATION

Views

  • 2509 Total Views
  • 1927 Website Views
  • 582 Embeded Views

Actions

  • 0 Social Shares
  • 1
  • 0
  • 0 Comments

Share count

  • 0  Facebook
  • 0  Twitter
  • 0  LinkedIn

Embeds 5

  • 29 www.sab-us.com
  • 8 161.97.92.48
  • 6 161.97.92.48:8011
  • 154 www.google.com
  • 8

Website Visitors - 504716