Public Channel / Data Sheets

Share on Social Networks

Share Link

Use permanent link to share in social media

Share with a friend

Please login to send this document by email!

Embed in your website

Select Link to start with 

4. 4 4/5 Sikaplan ® WP 1100 - 20HL Notes on Application / Limitations Installation works shall only be carried out by Sik a ® trained contractors, experienced in the lining of tunnels and undergroun d structures. The membrane is not resistant to permanent contact with materials including bitumen, and plastics other than PVC; on these it r equires a separation layer of geotextile (> 300 g/m 2 ). Sikaplan ® WP 1100 – 20HL is not suitable as sheet waterproofing membrane fo r tunnels, when exposed to permanent water temperatur e exceeding + 30°C and when exposed to polluted, or waste waters. It can b e exposed temporary to ground water or polluted water with temperature up to 50°C for 3 months. The water tightness of the structure must be approv ed after completion of the membrane installation works according to the requir ements of the client’s specifications. The membrane is not UV stabilised and must not be i nstalled on structures where it is permanently exposed to UV light and weathering. It can be exposed temporary to UV light up to 6 months.

5. 5 5/5 Sikaplan ® WP 1100 - 20HL Value Base All technical data stated in this Product Data Shee t are based on laboratory tests. Actual measured data may vary due to circumstances beyond our control. Local Restrictions Please note that as a result of specific local regu lations the performance of this product may vary from country to country. Please co nsult the local Product Data Sheet for the exact description of the product uses . Health and Safety Information For information and advice on the safe handling, st orage and disposal of chemical products, users shall refer to the most recent Mate rial Safety Data Sheet containing physical, ecological, toxicological and other safet y-related data. REACH European Community Regulation on chemicals an d their safe use (REACH: EC 1907/2006) This product is an article within the meaning of Re gulation (EC) No 1907/2006 (REACH). It contains no substances which are intend ed to be released from the article under normal or reasonably foreseeable cond itions of use. Therefore, there are no registration requirements for substances in articles within the meaning of Article 7.1 of the Regulation. Based on our current knowledge, this product does n ot contain SVHC (substances of very high concern) from the candidate list publi shed by the European Chemicals Agency in concentrations above 0.1 % (w/w). Protective Measures Fresh air ventilation must be ensured, when working (welding) in closed rooms. Local safety regulations must be observed. Transportation Class The product is not classified as hazardous good for transport. Disposal The material is recyclable. Disposal must be accord ing to local regulations. Legal Notes The information, and, in particular, the recommenda tions relating to the application and end-use of Sika products, are given in good fai th based on Sika's current knowledge and experience of the products when prope rly stored, handled and applied under normal conditions in accordance with Sika’s recommendations. In practice, the differences in materials, substrates and actual site conditions are such that no warranty in respect of merchantability or o f fitness for a particular purpose, nor any liability arising out of any legal relation ship whatsoever, can be inferred either from this information, or from any written r ecommendations, or from any other advice offered. The user of the product must test t he product’s suitability for the intended application and purpose. Sika reserves the right to change the properties of its products. The proprietary rights of third pa rties must be observed. All orders are accepted subject to our current terms of sale a nd delivery. Users must always refer to the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on requ est. Sika UAE L.L.C P.O. Box 126212 Dubai, United Arab Emirates Phone: +971 4 4398200 info@ae.sika.com http://gcc.sika.com Sika Gulf B.S.C (c) P.O. Box 15776 Adliya, Kingdom of Bahrain Phone: +973 17738 188 sika.gulf@bh.sika.com http://gcc.sika.com Sika Saudi Arabia Co. Ltd P.O. Box 112356, Jeddah 21371, Saudi Arabia Phone: +966 2 692 7079 jeddah@sa.sika.com http://gcc.sika.com Construction All products are manufactured under a management sy stem certified to conform to the requirements of th e quality, environmental and occupational health & safety stan dards ISO 9001, ISO 14001 and OHSAS 18001.

1. Product Data Sheet Edition: 01/02/2015 Identification no: 02 07 04 10 100 0 200000 Version no: GCC Sikaplan ® WP 1100-20HL 1 1/5 Construction Sikaplan® WP 1100 - 20HL Sikaplan ® WP 1100-20HL Sheet Waterproofing Membrane – Tunnel / Basement Product Description Sikaplan ® WP 1100-20HL is a homogenous sheet waterproofing membrane with a 0.6mm thick signal layer, based on polyvinyl chlori de (PVC-P). Suitable for use in hot and tropical climatic condi tions. Uses Sikaplan ® WP 1100-20HL is a sheet waterproofing membrane for use in tunne ls, basements and other underground structures. Characteristics / Advantages  Resistant to ageing  Optimised tensile strength and elongation  UV-stable (350MJ/m 2 acc. To EN 12224)  Resistant to root penetration  Dimensional stable  Without DEPH (DOP) plasticiser, based on virgin mat erial  Flexible in cold temperatures  Heat Weldable  Can be installed on wet substrates  Suitable for contact with acidic soft water (low pH aggressive to concrete)  High water vapour transmission ability  Not bitumen resistant Tests Standards / Approvals Product Declaration EN 13491 – Geosynthetic barrier s – Characteristics required for use as a fluid barrier in the construction of t unnels and underground structures. CE-Certificate No. 1349-CPD-028. Product Data Form Homogeneous rolled sheet membrane Appearance / Colour Surface: Smooth Colours: Top layer: Yellow (signal layer) Bottom layer: Dark grey Packaging Roll size: 2.20 m (roll width) x roll length indivi dual as specified Unit weight: 2.60 kg/m 2 Storage Storage Conditions Rolls shall be stored in their original package, in horizontal position and under cool and dry conditions. They shall be protected from di rect sunlight, rain, snow and ice, etc. Do not stack pallets of rolls during transport or s torage. Shelf Life Product does not expire if correctly stored.

3. 3 3/5 Sikaplan ® WP 1100 - 20HL Impact Resistance (500 g) No leakage at 750 mm EN 1107-2 (SIA V280-4; DIN 16 726-5.12) Long Term Compression Strength No leakage at 7 N/mm 2 , (50hr) SIA V280-14 Behaviour after Storage in Warm Water 8mt / 50°C Change of weight: ≤ 4.0% Change of tensile strength: ≤ 20% Change of elongation: ≤ 20% EN 1296 (SIA V280-13) Behaviour after Storage in Aqueous Solutions (28 d / 23°C), H 2 SO 3 (5%); Ca(OH) 2 (sat.); NaCI (10%) Change of tensile strength: ≤ 15% Change of elongation: ≤ 15% EN 1847 (SIA V280-18; DIN 16726-5.18) Behaviour of Welding Tensile shearing test: Break outside the welding s eam Short time welding factor: fz = ≥ 0.6 EN 12317-2 Peeling resistance: ≥ 6 N/mm EN 12316-2 Application Details System Structure Ancillary products: - Sikaplan ® WP Disc for fixing pieces - Sikaplan ® W Felt PP - Sikaplan ® W Tundrain Typ A - Sikaplan ® WP Protection sheet - Sika ® Waterbars WP, Types AR and DR for fixing pieces an d waterproofing concrete joints Substrate Quality In-situ concrete: Clean, sound and dry, homogeneous, free from oils a nd grease, dust and loose or friable particles. Shotcrete: The profile of the shotcrete surface must not excee d a ratio of length to depth of 5:1 and its min. radius must be 20 cm. The shotcrete surface must not contain broken aggre gates. Any leaks shall be sealed with Sika ® waterproof plugging mortars, or drained with Sika ® FlexoDrain. Where necessary to achieve the desired profile/surf ace, apply a fine sprayed concrete layer on the shotcrete surface with a min. thickness of 5 cm and aggregate diameter not exceeding 4 mm. Steel (girders, reinforcement mesh, anchors, etc.) must also be covered with a minimum 5 cm of fine sprayed concrete. The surface of the shotcrete and fine sprayed concr ete must be cleaned (no loose stones, nails, wires, etc.). Substrate Temperature 0°C min. / +35°C max. Ambient Temperature +5°C min. / +35°C max. For installation below +5°C ambient temperature, sp ecial measures for safety requirements may be required in accordance with rel evant national regulations. Ambient Temperature of Liquids +30°C maximum Application Method / Tools Installation method: Loose laid and mechanically fastened, or loose laid and ballasted in accordance with the separate Sika ® Method Statement and Application Manual for sheet waterproofing membrane installations. All membrane overlaps must be heat welded i.e. usin g hand welding guns and pressure rollers or automatic heat welding machines , with individually adjustable and electronically controlled welding temperatures (such as the manual Leister Triac PID / automatic: Leister Twinny S / semi-auto matic: Leister Triac Drive). Use Sika-Trocal ® Cleaner 2000 for seam preparation and cleaning of slightly soiled membrane surface. Welding parameters, such as speed and temperature m ust be established with trials on site, prior to any welding works.

2. 2 2/5 Sikaplan ® WP 1100 - 20HL Technical Data Chemical Base Polyvinyl Chloride (PVC-P) Thickness 2.0 mm (-5/+10%) EN 1849-2 Mass per Unit Area 2.60 kg/m 2 (-5/+10%) EN 1849-2 Water Permeability < 10 -7 m 3 x m -2 x d -1 (liquid tightness) EN 14150:2001 Tensile Strength Machine: 17.0 N/mm 2 (± 2.0) ISO R 527 – 1/3/5 Cross: 16.0 N/mm 2 (± 2.0) ISO R 527 – 1/3/5 Tear Strength Machine: ≥ 42 kN/m ISO 34 Method B; V=50 mm/min Cross: ≥ 42 kN/m ISO 34 Method B; V=50 mm/min Elongation Machine: ≥ 300% ISO R 527 – 1/3/5 Cross: ≥ 280% ISO R 527 – 1/3/5 Burst Strength ≥ 50% EN 14151 D=1,0 m Static Puncture 2.35 (± 0.25) kN EN ISO 12236 Low Temperature Behaviour ≤ - 20°C EN 495-5 Thermal Expansion 190 x 10 -6 (±50x10 -6 ) 1/K ASTM D 696-91 Weathering Remaining tensile strength and elongation: ≥ 75% EN 12224, 350 MJ/m 2 ISO 527-3/5/100 Micro Organism Change of tensile strength: ≤ 15% EN 12225; ISO 527-3/5 Change in elongation: ≤ 15 % EN 12225; ISO 527-3/5 Oxidation Change of tensile strength: ≤ 25% EN 14575; ISO 527-3/5 Change in elongation: ≤ 25% EN 14575; ISO 527-3/5 Environmental Stress Cracking This method of testing is only suitable for ASTM D 5397-99 (EN 14576) flexible polyolefin (FPO) based materials. Chemical Resistance A (hydrolyses under acid conditions): Change in elongation: ≤ 10% EN 14414: 2004-08; ISO 527-3/5 B (hydrolyses under alkaline conditions): Change in elongation: ≤ 10% EN 14414: 2004-08; ISO 527-3/5 D (artificial disposal water): Change in elongation: ≤ 10% EN 14414: 2004-08; ISO 527-3/5 Resistance to Root Penetration Pass EN 14416:2002 Reaction to Fire Class E EN ISO 11925-2 Behaviour under Hydrostatic Pressure 5 bar / 72hr (10 bar / 24hr) No leakage EN 1928 (DIN 16726-5.11) Thermal Ageing (70 d / 70°C) Change of weight: ≤ 2.0% Change of tensile strength: ≤ 20% Change of elongation: ≤ 20% EN 1296 (SIA V280-8) Elastic Modulus E 1-2 Machine and cross direction: ≤ 20 N/mm 2 ISO 527-1/3 Heat Distortion Dimensional Stability 6hr / 80°C Machine and cross direction: ≤ 2.0% Behaviour after heat exposure: No blisters EN 1107-2 (SIA V280-4; DIN 16726-5.13)

Views

  • 3850 Total Views
  • 2893 Website Views
  • 957 Embeded Views

Actions

  • 0 Social Shares
  • 1
  • 0
  • 0 Comments

Share count

  • 0  Facebook
  • 0  Twitter
  • 0  LinkedIn

Embeds 5

  • 128 www.sab-us.com
  • 31 161.97.92.48
  • 5 161.97.92.48:8011
  • 154 www.google.com
  • 8

Website Visitors - 510858